Runtime state and policy fields

These members report changing session state or select policies which OpenDoors consults after initialization. Their entries distinguish values which the application may change from reports which should be treated as read-only.

Diagnostics and input state

od_error

INT16 od_control.od_error;

od_error records the reason for the most recent OpenDoors API failure which assigned an error code. Its static-storage initial value is ERR_NONE. Initialization does not unconditionally reset it, because an initialization helper may already have reported a failure.

A successful API call normally leaves the previous value unchanged. The application must therefore test a function's documented return value first and inspect od_error only when that return indicates failure. Reading od_error == ERR_NONE after a successful call does not prove that no earlier call failed, and a nonzero stale value does not make a later successful call a failure.

The complete values are listed under Error codes. The application may inspect this field and may deliberately clear it to ERR_NONE for its own bookkeeping, but OpenDoors remains free to replace it on the next diagnosed failure.

During od_exit(), failure to open a supported text door-information file for rewriting or a binary EXITINFO.BBS record for updating stores ERR_FILEOPEN here, and an output or close failure stores ERR_GENERALFAILURE. An activity-log final-write or close failure also stores the same error; an oversized final-entry template stores ERR_LIMIT. Shutdown continues and retains the process error level requested by the application.

od_last_input

BYTE od_control.od_last_input;

After od_get_key() returns a character, this field is 0 if that event came from the remote caller and 1 if it came from the local operator. OpenDoors chat and example code use it to select the appropriate speaker or local-only command behavior.

The static-storage initial value is zero, but before the first returned key that value does not prove that remote input has occurred. The library writes the field; application code should normally read it without assigning it.

od_user_keyboard_on

BOOL od_control.od_user_keyboard_on;

This field controls whether remote caller keystrokes are admitted to the common OpenDoors input queue. Initialization sets it to TRUE. The local keyboard-off command—Alt-K in the standard personality—toggles it and updates the status indication. The Win32 local interface provides the equivalent command.

When the value is FALSE, the kernel discards newly received remote input; local operator keys remain available. The application may inspect the state or change it at runtime when implementing an equivalent policy. It is not a pre-initialization setting because initialization always enables the caller's keyboard.

Display and status state

od_cur_attrib

INT16 od_control.od_cur_attrib;

This field is OpenDoors' current logical IBM-PC text attribute. Initialization sets it to -1, meaning that the remote attribute is not yet known. od_set_attrib(), terminal emulation, screen clearing, menus, and chat update it as colors change. Values 0 through 255 have the representation described under Colors.

Application code may read the field when it must save and later restore the current color. It should change the display through od_set_attrib(), rather than assigning this member, because direct assignment sends no terminal command and does not update the virtual or local screen attribute.

od_current_statusline

BOOL od_control.od_current_statusline;

On text-mode targets, this report contains the setting most recently applied by od_set_statusline(): 0 through 7 for a personality status line or STATUS_NONE to remove it. The declared type is BOOL for historical ABI compatibility, but the stored value is not limited to true and false.

Static initialization supplies zero. Normal initialization activates the personality's initial status line and updates the member when the text-mode status subsystem is available. It is not an instruction field: assign a new setting by calling od_set_statusline().

od_update_status_now

BOOL od_control.od_update_status_now;

Setting this field to TRUE requests a forced redraw of the active local status line. During the next kernel update, OpenDoors redraws the current line even if its selection has not changed, then resets the field to FALSE.

Its static and normal default is FALSE. The application and personality SDK normally use ODStatForceStatusUpdate() rather than depending on this structure member directly, but direct runtime assignment retains its established effect.

od_chat_active

BOOL od_control.od_chat_active;

od_chat_active is true while OpenDoors' line-oriented sysop chat is active. It begins as FALSE; od_chat() and the local chat command set it to true, and chat cleanup restores false.

The chat loop tests this member on every iteration. Application code may set it to FALSE from an appropriate callback or cooperating execution context to request that chat end. Setting it to TRUE does not by itself create the chat loop, install callbacks, or enter chat mode; use od_chat() to begin a complete chat session.

od_silent_mode

BOOL od_control.od_silent_mode;

When assigned TRUE before initialization, this field suppresses the local OpenDoors user interface, including the local presentation and sysop command handling. It defaults to FALSE and can be enabled by the -SILENT command-line option.

On DOS and Windows, conventional local mode has baud == 0. Windows preserves an explicitly enabled silent mode, so a silent local session neither creates nor manages a console. Traditional non-Windows local initialization forces this field back to false. Unix-like standard-I/O sessions use different transport conventions and do not necessarily pass through that zero-baud case. OpenDoors reads the value throughout local-screen and kernel operation. Changing it after initialization does not reconstruct resources omitted at startup and is unsupported.

Time and paging state

od_inactive_warning

INT16 od_control.od_inactive_warning;

This field selects how many seconds before the inactivity deadline OpenDoors displays od_control.od_inactivity_warning, or passes that message to od_control.od_time_msg_func. Normal initialization unconditionally assigns 10 seconds. An application override must therefore be made after initialization.

The warning is used only while the inactivity limit is nonzero and od_control.od_disable_inactivity is false. OpenDoors emits it at most once between input events; new input resets the warning state. The field is read dynamically by od_kernel(), so a runtime change affects the next time check.

od_maxtime_deduction

INT16 od_control.od_maxtime_deduction;

This is the number of minutes temporarily removed from od_control.user_timelimit because the session's available BBS time exceeded od_control.od_maxtime. It begins at zero. If od_maxtime is between 1 and 1,440 and is less than user_timelimit, initialization stores the difference here and reduces user_timelimit to the cap.

During od_exit(), OpenDoors adds the deduction back before updating the door-information file. The field is maintained by the library and should be treated as read-only. Altering it changes the time value returned to the BBS.

od_okaytopage

BOOL od_control.od_okaytopage;

This tri-state field controls whether od_page() may page the sysop:

Value Policy
PAGE_DISABLE Never page.
PAGE_ENABLE Page regardless of configured hours.
PAGE_USE_HOURS Use od_pagestartmin and od_pageendmin.

Although the member is declared BOOL, it is not Boolean. Initialization unconditionally sets PAGE_USE_HOURS, so an application override must be made after initialization. The local personality may also change it at runtime.

od_pagestartmin

INT16 od_control.od_pagestartmin;

This field is the first minute of the daily paging interval, expressed as minutes after midnight. Initialization first assigns 480 (08:00). If the configuration file contains paging hours, the configuration component applies its parsed value after normal OpenDoors initialization. Application code may change the value afterward.

When od_okaytopage is PAGE_USE_HOURS, the beginning is inclusive. Values should be in the range 0 through 1,439.

od_pageendmin

INT16 od_control.od_pageendmin;

This field is the exclusive ending minute of the daily paging interval. Initialization first assigns 1,320 (22:00), after which configured paging hours can replace it. Application code may change it at runtime.

If the start is less than the end, the interval lies within one calendar day. If the start is greater, the interval crosses midnight. Equal start and end values permit paging for the entire day when PAGE_USE_HOURS is active.

od_page_pausing

BOOL od_control.od_page_pausing;

This field determines whether the display-file and file-listing interfaces pause after a screenful of output. For ordinary text drop files, initialization sets it to TRUE. Extended EXITINFO.BBS records replace it with bit 0x04 of user_attribute, the caller's stored pausing preference. A custom door-information definition may supply it explicitly.

od_send_file(), od_send_file_section(), and od_list_files() copy the setting when an operation begins. The application may change it after initialization; changing it during an active display does not necessarily change that operation's saved policy.

od_page_statusline

INT16 od_control.od_page_statusline;

This field selects the status line displayed while the caller is paging the sysop. Personality initialization supplies the effective default: the RemoteAccess personality uses line 5, the PCBoard personality uses line 0, and the standard, Wildcat, and MPS fallback paths use -1 to retain the current status line.

od_page() switches to the selected line only when the value is not -1 and a status line is currently active. It restores the previous line afterward. The application or a personality may change this field at runtime.

Local operator and BBS state

sysop_next

BYTE od_control.sysop_next;

This Boolean indicates that the BBS should reserve the system for the sysop after the current caller leaves. It begins as FALSE. SFDOORS.DAT and supported extended EXITINFO.BBS records can populate it. The standard local command—Alt-N in the built-in personalities—and the Win32 interface toggle it.

OpenDoors displays the current state and writes it back to formats which support the setting. The application may inspect or change it at runtime. A false value for a format which does not provide the field means only that the feature is not requested; it does not prove that the BBS supports it.

Compatibility-only state

od_last_hot

INT16 od_control.od_last_hot;

This field records the most recent application- or personality-defined local hot key recognized through od_hot_key. It is zero before any such key is pressed. On a match, OpenDoors stores the key code, notifies the active personality with PEROP_CUSTOMKEY, and then invokes the corresponding od_hot_function, if any.

OpenDoors does not clear the field after dispatch. A personality may clear it while handling PEROP_CUSTOMKEY; otherwise application code which polls the field should restore it to zero after processing the key. The value is written only for custom local hot keys and does not report built-in sysop commands, ordinary local input, or remote caller input.

od_max_key_latency

tODMilliSec od_control.od_max_key_latency;

This member is retained in tODControl for source and binary compatibility, but the current implementation never reads it. Its static value is zero and assigning it has no effect. Remote control-sequence decoding currently uses the internal 250-millisecond MAX_CHARACTER_LATENCY value between bytes.

The timeout passed to od_get_input() limits the wait for the first event and is independent of this compatibility member.

See also

od_kernel(), od_page(), od_set_statusline(), Customization fields